Human Glycosylation Array 507

Item no. GAH-GCM-507-4
Manufacturer Raybiotech
Amount 4 Sample Kit
Quantity options 4 Sample Kit 8 Sample Kit
Category
Type Glycobiology Arrays
Specific against Human
ECLASS 10.1 32161000
ECLASS 11.0 32161000
UNSPSC 41116126
Available
Number of Targets Detected
507
Compatible Sample Types
Cell Culture Supernatants
Cell Lysates
Plasma
Serum
Tissue Lysates
Design Principle
Sandwich-based
Method of Detection
Fluorescence Laser Scanner
Quantitative/Semi-Quantitative
Semi-Quantitative
Solid Support
Glass Slide
Application Information
Identify and profile the glycans in their samples
Determine whether their biomarker of interest has glycan moieties
Determine relative expression levels
Kit Components
Human Glycosylation Array 507 Glass Slide/s
Dilution Buffer20
X Wash Buffer I20
X Wash Buffer I
I
Cy3 equivalent dye-conjugated Streptavidin
Biotin-labeled Lectin Mixture
Adhesive device sealer
Manual
Other Materials Required
Pipettors, pipet tips and other common lab consumables
Orbital shaker or oscillating rocker
Aluminum foil
Distilled or de-ionized water1 ml microcentrifuge tubes
Gene microarray scanner or similar laser fluorescence scanner
Protocol Outline
Dry the glass slide
Incubate samples
Incubate with biotin lectin mixture
Incubate with Cy3 Equivalent Dye-
Streptavidin
Disassemble the glass slide
Scan with a gene microarray laser scanner
Perform densitometry and analysis
Product Features
High density screening
High sensitivity and specificity
Low sample volume (20-100 µl per array)
Large dynamic range of detection
Compatible with most sample types
Accurate and reproducible
Introduction
Recent technological advances by RayBiotech have enabled the largest commercially available glycosylation antibody array to date. With the Human Glycosylation Array 507, researchers can now efficiently obtain glycosylation profiles in their samples. The glycosylation profiles of 507 human proteins can be simultaneously detected, including, but not limited to, cytokines, chemokines, adipokines, growth factors, angiogenic factors, proteases, soluble receptors, soluble adhesion molecules in cell culture supernatants, serum, plasma and other samples types.Capture antibodies are printed onto glass slides and the glycans on these capture antibodies are removed. The glass slide arrays come pre-blocked and are ready to be incubated with samples. After incubation with samples and washing to remove unbound proteins, five unique biotin-labeled lectins are incubated with the array to allow binding to the glycans from captured target proteins. Streptavidin-conjugated fluorescent dye (Cy3 equivalent) is then added to the array. Finally, the glass slide is dried and laser fluorescence scanning is used to visualize the signals. These signals are then compared to the array map to identify glycosylated proteins present in the samples.
Typical Results
The following figure shows the RayBio® Human Glycosylation Antibody Array 507 probed with conditioned media sample. The images were captured using a Axon GenePix laser scanner. The strong signals in row 20 and the upper left and lower right corners of each array are Positive Controls, which can be used to identify the orientation and help normalize the results between arrays.
Biotin-Labeled Lectin Mixture
Lectin Name
Sugar specificity

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 4 Sample Kit
Available: In stock
available

Delivery expected until 12/20/2024 

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?