Comparison

CLIA Kit for Acetylcarnitine (ALCAR)

Item no. CCO400Ge-48T
Manufacturer Cloud-Clone
Amount 48 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Category
Type Clia
Applications IA
Specific against other
Sensitivity The minimum detectable dose of this kit is typically less than 7.7ng/mL
ECLASS 10.1 32161000
ECLASS 11.0 32161000
UNSPSC 41116126
Alias Acetyl-L-carnitine
Available
Specificity Pan-species (General)
Quantity options
Detection range
19.5-5, 000ng/mL
Organism species
Pan-species (General)
Sensitivity
The minimum detectable dose of this kit is typically less than 7.4ng/mL
Sample type
Serum, plasma and other biological fluids
Assay length
2h
Method
Competitive Inhibition
Specificity

This assay has high sensitivity and excellent specificity for detection of Acetylcarnitine (ALCAR).
No significant cross-reactivity or interference between Acetylcarnitine (ALCAR) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Acetylcarnitine (ALCAR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Acetylcarnitine (ALCAR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µ L standard or sample to each well.
        And then add 50µ L prepared Detection Reagent A immediately.
        Shake and mix. Incubate 1 hour at 37° C;
3. Aspirate and wash 3 times;
4. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C;
5. Aspirate and wash 5 times;
6. Add 100µ L Substrate Solution. Incubate 10 minutes at 37° C;
7. Read RLU value immediately.
Test principle
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Acetylcarnitine (ALCAR). A competitive inhibition reaction is launched between biotin labeled Acetylcarnitine (ALCAR) and unlabeled Acetylcarnitine (ALCAR) (Standards or samples) with the pre-coated antibody specific to Acetylcarnitine (ALCAR). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Acetylcarnitine (ALCAR) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Acetylcarnitine (ALCAR) level in the sample or standard.
Research Area
Metabolic pathway; Neuro science; Nutrition metabolism;

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 48 T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 