Item no. |
IEA443Ge-96T |
Manufacturer |
Cloud-Clone
|
Amount |
96T |
Category |
|
Type |
Elisa-Kit |
Specific against |
other |
ECLASS 10.1 |
32160605 |
ECLASS 11.0 |
32160605 |
UNSPSC |
41116126 |
Alias |
5alpha-DHT, 5alpha-Dihydrotestosterone, Androstanolone, Stanolone |
Available |
|
Quantity options |
|
Organism species |
Pan-species (General) |
Sensitivity |
The minimum detectable dose of this kit is typically less than |
Assay length |
1h, 10min |
Method |
Competitive Inhibition |
Specificity |
This assay has high sensitivity and excellent specificity for detection of Instant Dihydrotestosterone (DHT). No significant cross-reactivity or interference between Instant Dihydrotestosterone (DHT) and analogues was observed. |
Precision |
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Dihydrotestosterone (DHT) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Dihydrotestosterone (DHT) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12% |
Stability |
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. |
Assay procedure summary |
1. Prepare all reagents, samples and standards; 2. Add 50µ L standard or sample and 50µ L Detection Reagent A to each well. Incubate 1 hours at 37° C; 3. Aspirate and wash 3 times; 4. Add 90µ L Substrate Solution. Incubate 10-20 minutes at 37° C; 5. Add 50µ L Stop Solution. Read at 450nm immediately. |
Test principle |
The test principle applied in this kit is enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Instant Dihydrotestosterone (DHT). Standards or samples and HRP-labeled detection antibody specific to Instant Dihydrotestosterone (DHT) (Detection Reagent A) are then added to the appropriate microtiter plate wells. Next, TMB substrate solution is added, only those wells that contain Instant Dihydrotestosterone (DHT), and HRP-labeled detection antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Instant Dihydrotestosterone (DHT) in the samples is then determined by comparing the O.D. of the samples to the standard curve. |
Research Area |
Endocrinology; Reproductive science; Hormone metabolism; |
Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.