Rat Pro Atrial Natriuretic Peptide (Pro-ANP) ELISA Kit

Item no. ABK-KTE100418-96Tx50
Manufacturer Abbkine Scientific
Amount 96Tx50
Category
Type Elisa-Kit
Applications ELISA
Specific against Rat
ECLASS 5.1 32160605
ECLASS 6.1 32160605
ECLASS 8.0 32160605
ECLASS 9.0 32160605
ECLASS 10.0.1 32160605
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Available
Applications notes
This Rat Pro Atrial Natriuretic Peptide (Pro-ANP) ELISA Kit employs a two-site sandwich ELISA to quantitate Pro-ANP in samples. An antibody specific for Pro-ANP has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyPro-ANP present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for Pro-ANP is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of Pro-ANP bound in the initial step. The color development is stopped and the intensity of the color is measured.
Detection method
Colorimetric
Sample type
Cell culture supernatants#Serum#Plasma#Other biological fluids
Assay type
Sandwich ELISA (quantitative)
Assay duration
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Kit components

Rat Pro Atrial Natriuretic Peptide microplate
Rat Pro Atrial Natriuretic Peptide standard
Rat Pro Atrial Natriuretic Peptide detect antibody
Streptavidin-HRP
Standard diluent
Assay buffer
HRP substrate
Stop solution
Wash buffer
Plate covers
Features & Benefits
Rat Pro Atrial Natriuretic Peptide (Pro-ANP) ELISA Kit has high sensitivity and excellent specificity for detection of Rat Pro-ANP. No significant cross-reactivity or interference between Rat Pro-ANP and analogues was observed.
Usage notes
Do not mix components from different kit lots or use reagents beyond the kit expiration date.
Allow all reagents to warm to room temperature for at least 30 minutes before opening.
Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
Unused wells must be kept desiccated at 4 C in the sealed bag provided.
Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
It is recommended that all samples and standards be assayed in duplicate or triplicate.
Storage instructions
The unopened kit should be stored at 2 - 8C. After opening, please store refer to protocols.
Shipping
Gel pack with blue ice.
Precautions
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Background
Atrial natriuretic peptide (ANP), is a polypeptide hormone involved in the homeostatic control of body water, sodium, and adiposity. It is released by atrial myocytes, muscle cells in the atria of the heart, in response to high blood pressure. ANP acts to reduce the water, sodium and adipose loads on the circulatory system, thereby reducing blood pressure.ANP is a 28 amino acid peptide with a 17 amino acid ring in the middle of the molecule. The ring is formed by a disulfide bond between two cysteine residues at positions 7 and 23. ANP is closely related to BNP and CNP which all share the same amino acid ring. ANP was discovered in 1981 by a team in Ottawa led by Adolfo J. de Bold after they made the seminal observation that injection of atrial (but not ventricular) tissue extracts into rats caused copious natriuresis.
Alternative
Pro-ANP

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96Tx50
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close