Vergleich

MemGlow NR4A Membrane Polarity Probe ex 553 em 637 50-300 slides (MEMBRIGHT Family Probe)

ArtNr MG06-02
Hersteller Cytoskeleton
Menge 50-300 slides
Quantity options 50-300 slides 50-300 slides
Kategorie
Typ Reagents
Specific against other
ECLASS 10.1 42051003
ECLASS 11.0 42051003
UNSPSC 12000000
Lieferbar
Shipping Temperature
AT
Storage Conditions
On Arrival: 4°C
Description
MemGlow NR4A is a solvatochromic photostable plasma membrane-targeting dye with on/off switching that has been optimized for Super Resolution Point Accumulation for Imaging in Nanoscale Topography (SR-PAINT). Upon binding with a plasma membrane in a predominant liquid ordered (LO) phase NR4A exhibits a 45-50 nm wavelength shift relative to liquid disordered (Ld) phase enabling investigators to examine the nanoscale distribution of local chemical polarity in plasma membranes.
NR4A Membrane Polarity Probe Product Functions (MG06)
The NR4A Membrane Polarity Probe is the first probe that enables nanoscale cartography of the lipid order exclusively at the surface of live cells.
The NR4A Membrane Polarity Probe reveals nanoscopic protrusions and invaginations of lower Lipid Order in Plasma Membranes
High Specificity helps unveil rich nanoscale structural features of the plasma membrane
Weak Binders allow for better tracking of turn on events thanks to continuous flow exchange between the probe and membrane
For more detailed information on using this product see the About Tab
** 2 nmol of MemGlow will produce a 20uM stock solution when reconstituted with 100 ul of anhydrous DMSO
Weight (grams)
25
Figure 1 Legend
Figure 1. Diagram of NR4A's lipid order-dependent emission.
Figure 2 Legend
Figure 2. Absorbance and excitation spectra of MemGlow NR4A diluted in DMSO to 4.8 uM. Absorbance peak detected at 553 nm with peak emission at 637 nm.
Figure 3 Legend
Figure 3. A) Super resolution imaging of live HeLa cells labeled with 10 nM NR4A (false colored red). B) Widefield fluorescent imaging of live HeLa S1 cells labeled with 10 nM NR4A. HeLa S1 cells were imaged with a TRITC filter set, a digital CCD camera, and 100x oil objective (false colored red).

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 50-300 slides
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen