ArtNr |
ELH-VAP1-1 |
Hersteller |
Raybiotech
|
Menge |
1 Plate Kit |
Quantity options |
1 Plate Kit
2 Plate Kit
5 Plate Kit
|
Kategorie |
|
Typ |
Elisa-Kit |
Specific against |
Human |
Host |
Hamster - Armenian |
ECLASS 10.1 |
32160605 |
ECLASS 11.0 |
32160605 |
UNSPSC |
41116126 |
Lieferbar |
|
Specificity |
The antibody pair provided in this kit recognizes Human VAP-1 (AOC3) |
Design Principle |
Sandwich-based |
Method of Detection |
Colorimetric |
Quantitative/Semi-Quantitative |
Quantitative |
Solid Support |
96-well Microplate |
Gene Symbols |
AOC3VAP1 |
Kit Components |
Pre- Coated 96-well Strip Microplate Wash Buffer Stop Solution Assay Diluent(s) Lyophilized Standard Biotinylated Detection Antibody Streptavidin- Conjugated H R P T M B One- Step Substrate |
Other Materials Required |
Distilled or deionized water Precision pipettes to deliver 2 µl to 1 µl volumes Adjustable 1-25 µl pipettes for reagent preparation100 µl and 1 liter graduated cylinders Tubes to prepare standard and sample dilutions Absorbent paper Microplate reader capable of measuring absorbance at 450nm Log-log graph paper or computer and software for E L I S A data analysis |
Protocol Outline |
Prepare all reagents, samples and standards as instructed in the manual. Add 100 µl of standard or sample to each well. Incubate 2.5 h at R T or O/ N at 4° C. Add 100 µl of prepared biotin antibody to each well. Incubate 1 h at R T. Add 100 µl of prepared Streptavidin solution to each well. Incubate 45 min at R T. Add 100 µl of T M B One- Step Substrate Reagent to each well. Incubate 30 min at R T. Add 50 µl of Stop Solution to each well. Read at 450 nm immediately. |
Storage/Stability |
May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened Microplate Wells or reagents may be store for up to 1 month at 2° to 8°C. Return unused wells to the pouch containing desiccant pack, reseal along entire edge. Note: the kit can be used within one year if the whole kit is stored at -20°C. |
Protein Name & Synonyms |
Membrane primary amine oxidase (EC 1.4.3.21) (Copper amine oxidase) (HPAO) (Semicarbazide-sensitive amine oxidase) (SSAO) (Vascular adhesion protein 1) (VAP-1) |
Additional Notes |
Strip plates and additional reagents allow for use in multiple experimentsQuantitative protein detectionEstablishes normal rangeThe best products for confirmation of antibody array data |
Note |
This ELISA uses an antibody pair and standard that have been validated for multiplex array products, but not for the 96-well plate ELISA format. Thus, this ELISA requires a 4 - 7 week development phase, which RayBiotech begins after receiving an order for the kit. After development, the kit will have passed RayBiotech's ELISA quality control tests, and will thereafter have a typical 1 - 2 day lead time for orders placed. |
Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.
Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.