Vergleich

Human Autoimmune Disease IgG Autoantibody Array G1

ArtNr PAH-AIDG-G1-16
Hersteller Raybiotech
Menge 16 Sample Kit
Kategorie
Typ Array
Applikationen ELISA, other
Specific against Human (Homo sapiens)
Host Hamster - Armenian
ECLASS 10.1 32161000
ECLASS 11.0 32161000
UNSPSC 41116126
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Applications
Ig
G autoantibody profiling for following common autoimmune diseases, but may not be limited to
Systemic lupus erythematosus (
S
L
E)
Sjøgren's syndrome
Rheumatoid arthritis
Systemic Sclerosis/
C
R
E
S
T syndrome
Primary biliary cirrhosis
Autoimmune hepatitis
Hashimoto's thyroiditis
Polymyositis/
Dermatomyositis
System vasculitis
Celiac disease
The following table shows multiple Ig
G-type autoantibodies that can be detected in patient sera of different autoimmune diseases.
Autoimmune Diseases
Target No.
Autoimmunogens
Systemic lupus erythematosus (
S
L
E)#5ds
D
N
A#9
Histone H2
A#10
Histone H2
B#22
Proliferating Cell Nuclear Antigen (
P
C
N
A)#26
Scl-70 (
D
N
A topoisomerase-1)#33
U1-sn
R
N
P70 k
Da#12
Jo-1 (histidyl t
R
N
A synthetase, histidine-t
R
N
A ligase)#27
Sm/
Smith/sn
R
N
P core protein
Rheumatoid arthritis#21
C
C
P peptide#2
K
R
T8#11
K
R
T19#15
K
R
T20
Systemic Sclerosis / C
R
E
S
T Syndrome#4
Centromere Protein A (
C
E
N
P-
A)#3
Centromere B (
C
E
N
P-
B)#16
M/
Scl 100#27
Sm/
Smith/sn
R
N
P core protein
Primary biliary cirrhosis#8gp-210#17
M2#20
Nup62#28sp100
Autoimmune hepatitis#14
Liver cystolic antigen type 1 (
L
C-1)
Hashimoto's thyroiditis#30
Thyroglobulin (
T
G)#31
Thyroid peroxidase (
T
P
O)
Polymyositis / Dermatomyositis#1
Alanyl-t
R
N
A Synthetase (
P
L-12)#7
Glycyl-t
R
N
A Synthetase (
E
J)#18
Mi-2#29
Threonyl-t
R
N
A synthetase (
P
L-7)#14
Liver cystolic antigen type 1 (
L
C-1)
System vasculitis#19
Myeloperoxidase (
M
P
O), p-
A
N
C
A#23
Proteinase-3 (
P
R3), c-
A
N
C
A#3
Centromere B (
C
E
N
P-
B)
Sjøgren's syndrome#13
La/
S
S-
B#24
Ro/
S
S-
A (52 k
Da)#25
Ro/
S
S-
A (60 k
Da)
Celiac disease#6
Gliadin#32
Tissue Transglutaminase (t
T
G)
Number of Targets Detected
33
Compatible Sample Types
Serum
Design Principle
Sandwich-based
Method of Detection
Fluorescence Laser Scanner
Quantitative/Semi-Quantitative
Semi-Quantitative
Solid Support
Glass Slide
Gene Symbols
CALCA | CENPA | CENPB | GARS | HARS | KRT19 | KRT20 | KRT8 | MPO | NUP210|Â NUP62 | PCNA | PRTN3 | SNRNP70 | SP100 | SSB | TARS2 | TG | TGM2 | THPO | TOP1 | TRIM21
Kit Components
Ray
Bio® Human Autoimmune Disease Ig
G Autoantibody G1 array slide
Ray
Bio® G-series antibody array accessory (including slide incubation chamber assembly, gasket, protective cover, snap-on sides and adhesive film)
Blocking Buffer (8 ml/bottle)
Wash Buffer 1 (30 ml/bottle)
Wash Buffer 2 (30 ml/bottle)1, 000
X Biotin-conjugated anti-human Ig
G (1.5 µl/1 vial)1, 500
X Streptavidin-
Conjugated Fluor (1 µl/vial)
Other Materials Required
Small plastic boxes or containers
Orbital shaker or oscillating rocker
Pipettors, pipette tips and other common lab consumables
Distilled water
Aluminum foil
Laser scanner for fluorescence detection
Protocol Outline
See Manual for relevant protocols.
Below is the quick protocol for the experienced users.
Product Features
Small sample volume required (2 µl)
High density (simultaneously detect 33 autoantibodies)
High sensitivity
Large dynamic range
Suitable for high-throughput assays
High efficiency and accuracy
Affordable, quick and simple to use
Customizable: Tell us the autoimmunogens you're interested in
Storage/Stability
Upon receipt, all components of the RayBio® Human Protein Array kit should be stored at -20 °C to -80 °C until just before the experiment. At -20 °C to -80 °C the kit will retain complete activity for up to 6 months. Please use within six months of purchase. Once thawed, the array glass slide and Blocking Buffer should be kept at -20 °C and all other component should be stored at 4 °C. Use within three months after reagents have been thawed.
Typical Data
The following Figure 1 represents a typical result using serum on the RayBio® Autoimmune Disease IgG Autoantibody Detection Array (Cat #. PAH-AIDG-G1). The protein arrays were incubated with 200-fold diluted serum samples from normal individuals and patients with different autoimmune diseases. After washing steps, the arrays were sequentially incubated with biotin-labeled anti-human IgG antibody and fluorescent dye-labeled streptavidin. The signals from the bound autoantibodies were captured with a fluorescence scanner.
Sample diluent alone (Figs. 1A & 1B) and normal sera (Figs. 1C & 1D) were used as negative controls, and the arrays signals indicate that no significant background occurred. In some cases, a negligible signal can be observed, which may be caused by non-specific binding derived from the biotin-labeled anti-human IgG antibody and/or fluorescent dye-labeled streptavidin. However, these weak background signals will be subtracted in subsequent data analysis procedures and will not affect sample test results. A strong binding signal was detected in multiple targets among different autoimmune disease patients: systemic lupus erythematosus (Figs.1E & 1F), Sjøgren's syndrome (Figs.1G & 1H), system vasculitis (Figs.1I & 1J), and primary biliary cirrhosis (Figs.1K & 1L).
Fig 1. Typical result using serum on the RayBio® Autoimmune Disease IgG Autoantibody Detection Array. The protein arrays were incubated with diluent alone (A, B), diluted serum samples derived from normal individuals (C, D) and those from various autoimmune disease patients (E-L). Yellow boxes, show various controls as indicated (biotin-labeled BSA, human IgG and IgA).

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.