Vergleich

Human Obesity Array Q1

ArtNr QAH-ADI-1-2
Hersteller Raybiotech
Menge 22 Sample Kit
Quantity options 8 Sample Kit 22 Sample Kit 50 Sample Kit
Kategorie
Typ Array
Specific against Human (Homo sapiens)
Host Hamster - Armenian
ECLASS 10.1 32161000
ECLASS 11.0 32161000
UNSPSC 41116126
Similar products IL-1 alpha, IL-6, Insulin, Leptin, IL-8, Resistin, PAI-1, MCP-1, TNF alpha, IGF-2
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Applications
Multiplexed Protein Detection
Biomarker Screening
Identifying Key Factors
Confirming Biological Process
Biomarker Validation
Validation of Antibody Array Results
Quantitative Protein Detection
Establishing Normal Range
Number of Targets Detected
10
Compatible Sample Types
Cell Culture Supernatants
Cell Lysates
Other Body Fluids
Plasma
Serum
Tissue Lysates
Design Principle
Sandwich-based
Method of Detection
Fluorescence Laser Scanner
Quantitative/Semi-Quantitative
Quantitative
Solid Support
Glass Slide
Gene Symbols
CCL2CXCL8IGF1IL1BIL6INSLEPRETNSERPINE1TNF
Kit Components
Human Obesity Array Q1 Slide(s)
Blocking Buffer
Wash Buffer 1
Wash Buffer 2
Lyophilized Standard Mix
Biotinylated Detection Antibody Cocktail
Streptavidin-
Conjugated Fluor
Slide Washer/
Dryer
Adhesive Plastic Strips
Manual
Other Materials Required
Distilled or deionized water
Small plastic boxes or containers
Pipettors, pipette tips and other common lab consumables
Orbital shaker or oscillating rocker
Aluminum foil
Gene microarray scanner or similar laser fluorescence scanner
Protocol Outline
Dry the glass slide
Prepare Standards
Block array surface
Incubate with Samples and Standards
Incubate with Biotinylated Detection Antibody Cocktail
Incubate with Streptavidin-
Conjugated Fluor
Disassemble the glass slide
Scan with a gene microarray laser scanner
Perform densitometry and analysis
Product Features
More cost-effective than traditional ELISA
High specificity and system reproducibility
Suitable for diverse sample types
Low sample volume requirement: 50 µL or less
Get results same day (6-hour processing time)
Well-suited for high throughput assays
Q Analyzer software provides one-step computation
Pathway
Akt SignalingAMPK SignalingMAPK SignalingmTOR SignalingNFkB Signalingp53 SignalingPI3K-AKT Signaling

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 22 Sample Kit
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?