Vergleich

Precision Red Advanced Protein Assay (1X conc)

ArtNr ADV02-B
Hersteller Cytoskeleton
Menge 3 x 500 ml
Quantity options 1 x 500 ml 3 x 500 ml
Kategorie
Typ Proteins
Specific against other
Citations Castillo-Pichardo et al., 2013.  Dietary grape polyphenol resveratrol increases mammary tumor growth and metastasis in immunocompromised mice. BMC Complement. Altern. Med. 13:6.
Zilberter et al., 2013.  Dietary energy substrates reverse early neuronal hyperactivity in a mouse model of Alzheimer's disease. J. Neurochem.10.1111/jnc.12127.
ECLASS 10.1 32160409
ECLASS 11.0 32160409
UNSPSC 12352202
Alias Protein Assay, precision red, advanced protein assay, protein measurement, measure protein concentration
Similar products Protein Assay, protein measurement, precision red, advanced protein assay, measure protein concentration
Versandbedingung Raumtemperatur
Lieferbar
Shipping Temperature
AT
Storage Conditions
On Arrival: 4°C
Delivery Time
1-2 Weeks
FAQs

Question 1: Can I change the dilution volume of the experimental lysate being assayed?


Answer 1: Yes, different volumes of lysate can be used to quantify protein levels. The equation to determine protein concentration in µ, g/ml is: OD reading x dilution factor x 100 µ, g/ml/cm if a small volume (1.0 ml) cuvette is used. If a 96 well plate is used, the same equation is used with this single modification: 125 µ, g/ml/cm is the value used rather than 100 µ, g/ml/cm.


Question 2: Can this assay be performed using 96 well plates?


Answer 2: Yes, the protein assay can be performed in either small volume cuvettes (1.0 ml) or a 96 well plate.If a 96 well plate is used, the equation to determine protein concentration in µ, g/ml is: OD reading x dilution factor x 125 µ, g/ml/cm.

Weight (grams)
2722
Product Uses
Product uses include measuring protein in
Cell extracts
Serum samples
Medium to high protein concentration solutions
Protein requiring GLP and higher standards
Purified proteins and antibodies
Material
The Precision Red Advanced Protein Assay Reagent is designed to optimize the speed and accuracy of protein measurement. The reagent combines the useful properties of low protein to protein variance (See Fig 1) and a wide protein concentration for a robust assay. The assay can measure accurately protein concentrations ranging from 0.25 to 50 mg/ml and is detergent compatible. A simple one step procedure results in a red to blue color change within 1 min, which can be recognized by measuring absorbance at 600 nm.
This reagent is so reproducible with a wide range of proteins and protein concentrations that it is employed to accurately determine the concentration in all of Cytoskeleton, Inc's protein products.
Method
The Precision Red Advanced Protein Assay makes it very easy and quick to measure prottein concentrations. A general method looks as follows:
Mix protein solution with ADV02 reagent (e.g. 10 ul sample with 1.0 ml ADV02)
Incubate 1 min
Read absorbance at 600 nm
Detergent and chemical compatibility
The Precision Red Advanced Protein Assay is a highly stable assay and it tolerates a wide range of reagents. See the Advanced Protein Assay reagent compatibility page for a full list of reagents that have been tested.
Using the Precision Red Advanced Protein Assay in cell extracts
Since the Precision Red Advanced Protein Assay is highly compatible with non-ionic detergents (see the ADV Chemical tolerance page), this reagent is ideal for measuring protein concentrations in cell and tissue extracts. Furthermore, since protein concentration can be measured after only 1 min of incubation with the reagent, it allows the user to proceed with the experiment quicker than any other protein assay, something that can be of big importanceWhen working with labile cell extracts.
Cytoskeleton, Inc. recommends using ADV02 for all our kits and assays that involve cell or tissue lysis. In the G-LISA small G-protein activation kits, we have even included this reagent to ensure that the user gets the most accurate and quickest possible measurement of the protein concentration in the cell lysates generated.
Figure 1 Legend
Figure 1: The low protein to protein variance with ADV01 and ADV02. A comparison of ADV01, ADV02, Bradford and Lowry assays on five different proteins.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 3 x 500 ml
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?