Vergleich

COVID-19 Human IgG ELISA Kit

ArtNr IEQ-CoVS1RBD-IgG-1
Hersteller Raybiotech
Menge 1 Plate Kit
Kategorie
Typ Elisa-Kit
Specific against Human (Homo sapiens)
Host Hamster - Armenian
Dry ice Yes
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Versandbedingung Trockeneis
Lieferbar
Compatible Sample Types
Dried Blood
Plasma
Saliva
Serum
Design Principle
Indirect
Method of Detection
Colorimetric
Quantitative/Semi-Quantitative
Quantitative
Solid Support
96-well Microplate
Gene Symbols
IGG
Kit Components
S
A
R
S-
Co
V-2 N-protein coated 96-well microplate
Wash Buffer
Positive Control
Biotinylated Anti-
Human Ig
G
H
R
P-
Streptavidin concentrate
T
M
B One-
Step Substrate
Stop Solution
Assay Diluent5
X Sample Diluent1
X P
B
S (
D
B
S version)
Tween-20 (
D
B
S version)
Protease Inhibitor Cocktail (
D
B
S version)
Other Materials Required
Microplate reader capable of measuring absorbance at 450 nm
Precision pipettes to deliver 2 µl to 1 ml volumes
Adjustable 1-25 ml pipettes for reagent preparation100 ml and 1 liter graduated cylinders
Tubes to prepare standard and sample dilutions
Absorbent paper
Distilled or deionized water
Protocol Outline
Prepare all reagents, samples and standards as instructed.
Add 100 µl positive control or sample to each well. Incubate 1 hour at room temperature.
Add 100 μl prepared Biotinylated Anti-
Human Ig
G Antibody into each well. Incubate 30 minutes at room temperature.
Add 100 μl prepared H
R
P-
Streptavidin solution to each well. Incubate 30 minutes at room temperature.
Add 100 µl T
M
B One-
Step Substrate Reagent to each well. Incubate 15 minutes at room temperature.
Add 50 µl Stop Solution to each well. Read at 450 nm immediately.
Storage/Stability
The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. For extended storage, it is recommended to store at -80°C.
Note
This Product is for Research Use Only, not for use in in vitro diagnostics, following guidance from the FDA for tests submitted to the FDA for Emergency Use Authorization and Notification on March 16th, 2020, and amended on May 4th, 2020. While this test has been submitted for FDA EUA Authorization, it currently has not been reviewed by the FDA and results from antibody testing should not be used as the sole basis to diagnose or exclude SARS-CoV-2 infection or to inform infection status. Please consult the manual for specific details and limitations of this test.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 1 Plate Kit
Lieferbar: In stock
lieferbar

Lieferung vsl. bis 24.01.2025 

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?