ArtNr |
CCA461Ge-10x96T |
Hersteller |
Cloud-Clone
|
Menge |
10x96 T |
Quantity options |
10x96 T
24 T
48 T
5x96 T
96 T
|
Kategorie |
|
Typ |
Elisa-Kit |
Applikationen |
IA |
Specific against |
other |
Sensitivity |
The minimum detectable dose of this kit is typically less than 5.55pg/mL |
Citations |
Growth differential factor-9 inhibits testosterone production in mouse theca interstitial cells Assessment of ADMA, estradiol, and progesterone in severe preeclampsia Protective effects of irbesartan and benazepril against vaginal vascular remodeling and fibrosis in female spontaneously hypertensive rats |
ECLASS 10.1 |
32160605 |
ECLASS 11.0 |
32160605 |
UNSPSC |
41116126 |
Alias |
17B-Estradiol; Oestradiol; Beta-Estradiol |
Lieferbar |
|
Specificity |
Pan-species (General) |
Quantity options |
|
Detection range |
12.35-1, 000pg/mL |
Organism species |
Pan-species (General) |
Sensitivity |
The minimum detectable dose of this kit is typically less than 5.55pg/mL |
Sample type |
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay length |
2h |
Method |
Competitive Inhibition |
Specificity |
This assay has high sensitivity and excellent specificity for detection of Estradiol (E2). No significant cross-reactivity or interference between Estradiol (E2) and analogues was observed. |
Precision |
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Estradiol (E2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Estradiol (E2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12% |
Stability |
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. |
Assay procedure summary |
1. Prepare all reagents, samples and standards; 2. Add 50µ L standard or sample to each well. And then add 50µ L prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37° C; 3. Aspirate and wash 3 times; 4. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C; 5. Aspirate and wash 5 times; 6. Add 100µ L Substrate Solution. Incubate 10 minutes at 37° C; 7. Read RLU value immediately. |
Test principle |
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Estradiol (E2). A competitive inhibition reaction is launched between biotin labeled Estradiol (E2) and unlabeled Estradiol (E2) (Standards or samples) with the pre-coated antibody specific to Estradiol (E2). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Estradiol (E2) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Estradiol (E2) level in the sample or standard. |
Research Area |
Endocrinology; Reproductive science; Hormone metabolism; |
Reference |
|
Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.
Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.