Vergleich

ELISA Kit for Anti-Nephrin Antibody (Anti-NPHN)

ArtNr AEA937Hu-10x96T
Hersteller Cloud-Clone
Menge 10x96T
Kategorie
Typ Elisa
Specific against Human
Sensitivity The minimum detectable dose of this kit is typically less than 1.22ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias NPHS1; CNF; Nephrosis 1; Congenital Finnish Type; Renal glomerulus-specific cell adhesion receptor
Lieferbar
Specificity This assay has high sensitivity and excellent specificity for detection of Anti-Nephrin Antibody (Anti-NPHN).
No significant cross-reactivity or interference between Anti-Nephrin Antibody (Anti-NPHN) and analogues was observed.
Manufacturers Category
ELISA Kit
Application
Enzyme-linked immunosorbent assay for Antibody Detection.
Sample type
serum, plasma and other biological fluids
Assay length
2h, 30min
Method
Competitive Inhibition
Precision
Intra-assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100uL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Nephrin Antibody (Anti-NPHN) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Nephrin Antibody (Anti-NPHN) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Item Name
Nephrin
Manufacturers Research Field
Tumor immunity; Kidney biomarker;

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 10x96T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen