ArtNr |
ADV02-A |
Hersteller |
Cytoskeleton
|
Menge |
1 x 500 ml |
Quantity options |
1 x 500 ml
3 x 500 ml
|
Kategorie |
|
Typ |
Proteins |
Specific against |
other |
Citations |
Castillo-Pichardo et al., 2013. Dietary grape polyphenol resveratrol increases mammary tumor growth and metastasis in immunocompromised mice. BMC Complement. Altern. Med. 13:6. Zilberter et al., 2013. Dietary energy substrates reverse early neuronal hyperactivity in a mouse model of Alzheimer's disease. J. Neurochem.10.1111/jnc.12127. |
ECLASS 10.1 |
32160409 |
ECLASS 11.0 |
32160409 |
UNSPSC |
12352202 |
Alias |
Protein Assay, precision red, advanced protein assay, protein measurement, measure protein concentration |
Similar products |
Protein Assay, protein measurement, precision red, advanced protein assay, measure protein concentration |
Versandbedingung |
Raumtemperatur |
Lieferbar |
|
Shipping Temperature |
AT |
Storage Conditions |
On Arrival: 4°C |
Delivery Time |
1-2 Weeks |
FAQs |
Question 1: Can I change the dilution volume of the experimental lysate being assayed? Answer 1: Yes, different volumes of lysate can be used to quantify protein levels. The equation to determine protein concentration in µ, g/ml is: OD reading x dilution factor x 100 µ, g/ml/cm if a small volume (1.0 ml) cuvette is used. If a 96 well plate is used, the same equation is used with this single modification: 125 µ, g/ml/cm is the value used rather than 100 µ, g/ml/cm. Question 2: Can this assay be performed using 96 well plates? Answer 2: Yes, the protein assay can be performed in either small volume cuvettes (1.0 ml) or a 96 well plate.If a 96 well plate is used, the equation to determine protein concentration in µ, g/ml is: OD reading x dilution factor x 125 µ, g/ml/cm. |
Weight (grams) |
908 |
Product Uses |
Product uses include measuring protein in Cell extracts Serum samples Medium to high protein concentration solutions Protein requiring GLP and higher standards Purified proteins and antibodies |
Material |
The Precision Red Advanced Protein Assay Reagent is designed to optimize the speed and accuracy of protein measurement. The reagent combines the useful properties of low protein to protein variance (See Fig 1) and a wide protein concentration for a robust assay. The assay can measure accurately protein concentrations ranging from 0.25 to 50 mg/ml and is detergent compatible. A simple one step procedure results in a red to blue color change within 1 min, which can be recognized by measuring absorbance at 600 nm. This reagent is so reproducible with a wide range of proteins and protein concentrations that it is employed to accurately determine the concentration in all of Cytoskeleton, Inc's protein products. |
Method |
The Precision Red Advanced Protein Assay makes it very easy and quick to measure prottein concentrations. A general method looks as follows: Mix protein solution with ADV02 reagent (e.g. 10 ul sample with 1.0 ml ADV02) Incubate 1 min Read absorbance at 600 nm |
Detergent and chemical compatibility |
The Precision Red Advanced Protein Assay is a highly stable assay and it tolerates a wide range of reagents. See the Advanced Protein Assay reagent compatibility page for a full list of reagents that have been tested. |
Using the Precision Red Advanced Protein Assay in cell extracts |
Since the Precision Red Advanced Protein Assay is highly compatible with non-ionic detergents (see the ADV Chemical tolerance page), this reagent is ideal for measuring protein concentrations in cell and tissue extracts. Furthermore, since protein concentration can be measured after only 1 min of incubation with the reagent, it allows the user to proceed with the experiment quicker than any other protein assay, something that can be of big importanceWhen working with labile cell extracts. Cytoskeleton, Inc. recommends using ADV02 for all our kits and assays that involve cell or tissue lysis. In the G-LISA small G-protein activation kits, we have even included this reagent to ensure that the user gets the most accurate and quickest possible measurement of the protein concentration in the cell lysates generated. |
Figure 1 Legend |
Figure 1: The low protein to protein variance with ADV01 and ADV02. A comparison of ADV01, ADV02, Bradford and Lowry assays on five different proteins. |
Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.
Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.