ArtNr |
BM-EKU08759 |
Hersteller |
Biomatik
|
Menge |
96T |
Kategorie |
|
Typ |
Elisa-Kit |
Format |
96 well plate |
Applikationen |
ELISA |
Specific against |
General |
ECLASS 10.1 |
32160605 |
ECLASS 11.0 |
32160605 |
UNSPSC |
41116126 |
Lieferbar |
|
Detection Range |
3.70-300 ng/mL |
Sensitivity |
1.41 ng/mL |
Sample Type |
Biological agents |
Assay Time |
2 hours |
Gene Name |
Taurocholic Acid |
Gene Aliases |
Cholaic Acid; Cholyltaurine; Acidum Cholatauricum |
Assay Type |
Competitive |
Detection Method |
Colorimetric |
Shipping Condition |
Blue ice |
Storage Instructions |
-20C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles. |
Precaution of Use |
The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption. |
Expiry Date |
8 months |
Specificity |
This assay has high sensitivity and excellent specificity for detection of Taurocholic Acid (TCA). No significant cross-reactivity or interference between Taurocholic Acid (TCA) and analogues was observed. |
Test Principle |
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Taurocholic Acid (TCA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Taurocholic Acid (TCA) and unlabeled Taurocholic Acid (TCA) (Standards or samples) with the pre-coated antibody specific to Taurocholic Acid (TCA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Taurocholic Acid (TCA) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Taurocholic Acid (TCA) in the sample. |
Assay Precision |
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Taurocholic Acid (TCA) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Taurocholic Acid (TCA) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12% |
Stability |
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. |
Restrictions |
For research use only. Not for diagnostic procedures. |
Quality Systems |
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities. |
Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.