Vergleich

Furazolidone (AOZ) ELISA Kit

Hersteller Abebio
Kategorie
Typ Elisa-Kit
Specific against other
Menge 48T
ArtNr ABE-AE81002SF-48T
eClass 6.1 32160605
eClass 9.0 32160605
Lieferbar
Abbreviation
AOZ
Range
0.02-1.62 ppb
Sensitivity
0.02 ppb
Sample Type
Tissue, liver, honey, milk, intestine, etc.
Detection Method
Competitive ELISA
Analysis Method
Quantitive
Assay Duration
1-3h
Sample Volume
10-200 uL
Detection Wavelengt
450 nm
Availability
3-5 working days
Test principle
This assay is based on the competitive enzyme immunoassay for the detection of AOZ in the sample. The coupling antigens are pre-coated on the micro-well stripes. The AOZ in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-AOZ antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the AOZ in it. This value is compared to the standard curve and the AOZ concentration is subsequently obtained.
Product Overview
Furazolidone is a nitrofuran antibacterial. It is marketed by Roberts Laboratories under the brand name Furoxone and by GlaxoSmithKline as Dependal-M. Furazolidone has been used in human and veterinary medicine. It has a broad spectrum of activity being active against. Furazolidone is no longer available in the US. Though an effective antibiotic when all others fail, against extremely drug resistant infections, it has many side effects, and as with other nitrofurans generally, minimum inhibitory concentrations also produce systemic toxicity (tremors, convulsions, peripheral neuritis, gastrointestinal disturbances, depression of spermatogenesis.) Nitrofurans are recognized by FDA as mutagens/carcinogens, and can no longer be used since 1991.
Precision
Intra-assay Precision (Precision within an assay)
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays)
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
CV (%) = SD/meanX100
Intra-Assay: CV<8%
Inter-Assay: CV<12%
Stability
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37C for 4 and 7 days, and compare O.D.values of the kit kept at 37C with that of at recommended temperature. (referring from China Biological Products Standard, which was calculated by the Arrhenius equation. For ELISA kit, 4 days storage at 37C can be considered as 6 months at 2 - 8C, which means 7 days at 37C equaling 12 months at 2 - 8C).
Storage
Store at 2-8C. Please refer to Instruction Manual.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 48T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen